Facade insulation

Důležitou funkcí obvodové stěny je, vedle základních funkcí bezpečnosti a statiky, také ochrana proti vnějším klimatickým podmínkám. Nezávisle na tom, zda je léto nebo zima, zateplení fasády vám přináší tepelný komfort. Kvalitním návrhem a odborně provedenou realizací systémového zateplení fasády lze snížit tepelné ztráty o více než 50%. Dobře zateplená fasáda také zamezí pronikání hluku z rušného městského prostředí.

VĂ­ce o aplikaci

Apply filters
Filter
Sort by:

Panel Solr Search Content Block

Filter your result Reset Apply filters
Filter
22 results

ISOVER EPS Greywall SP

<p>Lambda λ = 0,030</p>ISOVER EPS GreyWall Sun Protect facade insulation boards (abbreviated as GreyWall SP) are the latest and most potent type of gray EPS façade boards for ETICS thermal insulation systems. They are made from the best raw materials available on the technology market, which provides them with several unique properties.

ISOVER Uni

Lambda λ = 0,035

Insulating slabs made of ISOVER mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects (outer cassette sheathing, diffusion and vapour-proof foil).

ISOVER Woodsil

Lambda λ = 0,035

Insulating slabs made of ISOVER mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects (outer sheathing, alternatively diffusion foil).

ISOVER Evo

Lambda λ = 0,035

Insulating roll made with glass wool ISOVER 4+. The mineral fibres produced are processed into the final mat shape on the production line. Made in Italy with at least 80% of recycled glass and with an exclusive, patented binder, that ensures maximum indoor air quality. The insulation is not harmful to the environment or public health, and it is resistant to moulds, fungi and wood-destroying insects. The insulation in the construction should be properly protected (vapourproof foil, suitable protection against dust)

ISOVER Multimax 30

<p>Lambda λ = 0,030</p>Insulating slabs made of Isover fibreglass wool. The production method is
based on the fibering of glass melt and other additives and ingredients.
The mineral fibres produced are processed into the final slab shape on
the production line. The entire fibre surface is hydrophobic. The slabs in
the construction should be protected suitably against the weather effects
(outer cassette sheathing, diffusion and vapour-proof foil).

ISOVER Multiplat 35

<p>Lambda λ = 0,035</p>Insulation slabs made of ISOVER fibreglass wool. The production is based on
defibration of melt of glass and other additives and ingredients. Produced
mineral fibres are then shaped into slabs on the production line. Fibres are
made water-repellent on their entire surface. Slabs in construction have to
be protected suitably (steam protection foil, protection from dust settling,
other layers of construction).

ISOVER TF

Lambda λ = 0,038

Insulating slabs made of ISOVER mineral wool with longitudinal fibres. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction have to be protected suitably (layers of the contact wall insulation system).

ISOVER Twinner - rohové desky

<p>Lambda λ = </p>Twinner is a sandwich thermal and noise insulation board made of ISOVER EPS Greywall graphite insulation core with enhanced insulating effect and a 30 mmthick ISOVER TF Profi cover layer. Bonding is achieved using an industrial polyurethane adhesive that ensures high tensile and shear strength and enables efficient production of 100–300 mm-thick insulation boards for energy-efficient buildings. Isover Twinner insulation boards are manufactured using the latest CFC-/HCFC (also known as Freon) -free technologies. The EPS insulating component has a self-extinguishing design with improved fire safety.

ISOVER Twinner - zakládací desky

<p>Lambda λ = </p>Twinner is a sandwich thermal and noise insulation board made of ISOVER EPS Greywall graphite insulation core with enhanced insulating effect and a 30 mmthick ISOVER TF Profi cover layer. Bonding is achieved using an industrial polyurethane adhesive that ensures high tensile and shear strength and enables efficient production of 100–300 mm-thick insulation boards for energy-efficient buildings. Isover Twinner insulation boards are manufactured using the latest CFC-/HCFC (also known as Freon) -free technologies. The EPS insulating component has a self-extinguishing design with improved fire safety.

ISOVER Twinner - základní desky

<p>Lambda λ = 0,032</p>TWINNER is a sandwich thermal and noise insulation board made of Isover EPS GreyWall graphite insulation core with enhanced insulating effect and a 30 mmthick ISOVER TF Profi cover layer. Bonding is achieved using an industrial polyurethane adhesive that ensures high tensile and shear strength and enables efficient production of 100–300 mm-thick insulation boards for energy-efficient buildings. ISOVER TWINNER insulation boards are manufactured using the latest CFC-/HCFC (also known as Freon) -free technologies. The EPS insulating component has a self-extinguishing design with improved fire safety.

ISOVER NF 333

Lambda λ = 0,041

Insulating slabs made of ISOVER mineral wool with perpendicular fibres. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic and the fibres are perpendicular to the wall plane. The slabs in the construction have to be protected suitably (layers of the contact wall insulation system).